PYROGENT®-5000 Bulk Kinetic Turbidimetric Reconstitution BufferCatalog #: B50-600U
Reconstitution Buffer for PYROGENT®-5000 Bulk Kinetic Turbidimetric LAL Assay for T50-600U, 100 vials
Sales unit: each -
Nebula® Absorbance ReaderCatalog #: 25-365S
The Nebula® Absorbance Reader is a 96-well microplate reader that brings new and improved technology to the laboratory and is optimized to work with WinKQCL® Endotoxin Detection and Analysis Software and our traditional LAL assays such as the PYROGENT® 5000 Kinetic Turbidimetric Assay and the Kinetic-QCL® Kinetic Chromogenic Assay.
Sales unit: each -
Control Standard EndotoxinCatalog #: 7460L
Endotoxin for PYROGENT®-5000 Bulk Kinetic Turbidimetric LAL, E. coli Strain O55:B5, 25 vials
Sales unit: each -
-
PyroGene® Recombinant Factor C Endpoint Fluorescent AssayCatalog #: 50-658U
Recombinant Factor C Endpoint Fluorescent Assay for endotoxin testing up to 192 tests.
Sales unit: each -
PyroGene® Bulk Recombinant Factor C Endpoint Fluorescent AssayCatalog #: 50-658NV
Recombinant Factor C Endpoint Fluorescent Assay for endotoxin testing up to 2,880 tests.
Sales unit: each -
PYROGENT®-5000 Kinetic Turbidimetric LAL Assay, 100 Test KitCatalog #: N383Bulk turbidimetric kinetic LAL Assay for endotoxin testing for 100 tests. Kit contains endotoxin and reconstitution buffer. Assay sensitivity: 0.01 to 100 EU/ml.Sales unit: each
-
Control Standard Endotoxin for QCL-1000® Endpoint Chromogenic LAL, E. coli Strain 0111:B4Catalog #: E50-640
Endotoxin for QCL-1000® LAL Assay
Sales unit: each -
4D-Nucleofector® Y UnitCatalog #: AAF-1003Y
Enables the direct Nucleofection® of cells in adherence in 24-well culture plates
Sales unit: items -
4D-Nucleofector® 96-well UnitCatalog #: AAF-1003S
The medium-throughput module for the 4D-Nucleofector® Platform suited for transfection of hard-to-transfect cell lines or primary cells in 96-well format
Sales unit: items
-
Troubleshooting Guide - PYROGENT® Gel Clot LAL AssayMost problems encountered in the use of the PYROGENT® Gel Clot Limulus Amebocyte Lysate (LAL) Assay fall into two basic categories - no firm gels are observed in reaction tubes where firm gels are expected or firm gels form in reaction tubes, which are expected to yield negative results. This Tech Tip takes a deeper look into each of these categories and provides troubleshooting guidance.
-
Instructions - PYROGENT™ and PYROGENT™ Plus (Chinese)Detailed instructions for performing the PYROGENT™ and PYROGENT™ Plus Gel Clot LAL Assay
-
Instructions - PYROGENT® and PYROGENT® Plus (English)Detailed instructions for performing the PYROGENT® and PYROGENT® Plus Gel Clot LAL Assay
-
Troubleshooting Guide - Gel Clot LAL Assay Procedure (German)A step-by-step guide depicting how to perform a traditional gel clot LAL assay.
-
How To Perform The PYROGENT™ Gel Clot LAL AssayThe gel clot LAL assay is a qualitative test that provides simple positive-negative results. This video demonstrates how to perform the assay from start to finish. -
Troubleshooting Guide - Testing Oil Solutions with PYROGENT® Gel Clot LAL AssayEndotoxins, due to their lipid character, tend to remain associated with oils and do not readily enter the aqueous phase of water-oil mixtures. This Tech Tip describes the use of a dispersing agent, PYROSPERSE®, to allow for dissociation of the endotoxin from the oils and for subsequent detection of endotoxin in the aqueous phase by the PYROGENT® Gel Clot LAL Assay.
-
Troubleshooting Guide - Gel Clot LAL Assay Procedure (English)A step-by-step guide depicting how to perform a traditional gel clot LAL assay.
-
Troubleshooting Guide - Gel Clot LAL Assay Procedure (French)A step-by-step guide depicting how to perform a traditional gel clot LAL assay.
-
Troubleshooting Guide - Gel Clot LAL Assay Procedure (Japanese)A step-by-step guide depicting how to perform a traditional gel clot LAL assay.
-
Troubleshooting Guide - Gel Clot LAL Assay Procedure (Portuguese)A step-by-step guide depicting how to perform a traditional gel clot LAL assay.