PYROGENT®-5000 Kinetic Turbidimetric LAL AssayCatalog #: N384Bulk turbidimetric kinetic LAL Assay for endotoxin testing for 200 tests. Kit contains endotoxin and reconstitution buffer. Assay sensitivity: 0.01 to 100 EU/ml.Sales unit: each
-
LAL Reagent Grade Multi-well PlatesCatalog #: 25-340
96-well individually wrapped microplate specific for endotoxin testing.
Sales unit: units -
LAL Reagent Grade 96-well PlatesCatalog #: 00313405
96-well plates intended for use with LAL-based endotoxin assays
Sales unit: each -
Control Standard EndotoxinCatalog #: 7460L
Endotoxin for PYROGENT®-5000 Bulk Kinetic Turbidimetric LAL, E. coli Strain O55:B5, 25 vials
Sales unit: each -
PYROGENT®-5000 Kinetic Turbidimetric LAL Assay, 100 Test KitCatalog #: N383Bulk turbidimetric kinetic LAL Assay for endotoxin testing for 100 tests. Kit contains endotoxin and reconstitution buffer. Assay sensitivity: 0.01 to 100 EU/ml.Sales unit: each
-
Nebula® Absorbance ReaderCatalog #: 25-365S
The Nebula® Absorbance Reader is a 96-well microplate reader that brings new and improved technology to the laboratory and is optimized to work with WinKQCL® Endotoxin Detection and Analysis Software and our traditional LAL assays such as the PYROGENT® 5000 Kinetic Turbidimetric Assay and the Kinetic-QCL® Kinetic Chromogenic Assay.
Sales unit: each -
Nebula® Multimode ReaderCatalog #: 25-375S
The Nebula® Multimode Reader is part of the quantitative endotoxin detection system that supports both absorbance and fluorescent based endotoxin detection assays.
Sales unit: each -
Kinetic-QCL® Kinetic Chromogenic LAL Assay, 192 Test KitCatalog #: 50-650U
Kinetic Chromogenic LAL Assay for endotoxin detection for 192 tests, assay sensitivity: 0.005 - 50 EU/mL
Sales unit: each -
Kinetic-QCL® Bulk Kinetic Chromogenic LAL Assay, 2400 Test KitCatalog #: 50-650HBulk Kinetic Chromogenic LAL Assay for endotoxin detection for 2400 tests. Kit contains endotoxin. Assay sensitivity: 0.005 - 50 EU/mLSales unit: each
-
Kinetic-QCL® Bulk Kinetic Chromogenic LAL Assay, 2040 Test KitCatalog #: 50-650NVBulk Kinetic Chromogenic LAL Assay for endotoxin detection for 2040 tests. Kit contains endotoxin. Assay sensitivity: 0.005 - 50 EU/mLSales unit: each
-
Troubleshooting Guide - PYROGENT® Gel Clot LAL AssayMost problems encountered in the use of the PYROGENT® Gel Clot Limulus Amebocyte Lysate (LAL) Assay fall into two basic categories - no firm gels are observed in reaction tubes where firm gels are expected or firm gels form in reaction tubes, which are expected to yield negative results. This Tech Tip takes a deeper look into each of these categories and provides troubleshooting guidance.
-
Troubleshooting Guide - Gel Clot LAL Assay Procedure (English)A step-by-step guide depicting how to perform a traditional gel clot LAL assay.
-
Troubleshooting Guide - Gel Clot LAL Assay Procedure (French)A step-by-step guide depicting how to perform a traditional gel clot LAL assay.
-
Troubleshooting Guide - Gel Clot LAL Assay Procedure (Japanese)A step-by-step guide depicting how to perform a traditional gel clot LAL assay.
-
Troubleshooting Guide - Gel Clot LAL Assay Procedure (Portuguese)A step-by-step guide depicting how to perform a traditional gel clot LAL assay.
-
Troubleshooting Guide - Gel Clot LAL Assay Procedure (Spanish)A step-by-step guide depicting how to perform a traditional gel clot LAL assay.
-
Troubleshooting Guide - Gel Clot LAL Assay Procedure (Italian)A step-by-step guide depicting how to perform a traditional gel clot LAL assay.
-
Troubleshooting Guide - Gel Clot LAL Assay Procedure (German)A step-by-step guide depicting how to perform a traditional gel clot LAL assay.
-
Troubleshooting Guide - Gel Clot LAL Assay Procedure (Chinese)A step-by-step guide depicting how to perform a traditional gel clot LAL assay.
-
How To Perform The PYROGENT™ Gel Clot LAL AssayThe gel clot LAL assay is a qualitative test that provides simple positive-negative results. This video demonstrates how to perform the assay from start to finish.