PyroWave® XM Fluorescence Reader
PyroWave® XM Fluorescence Reader
The PyroWave® XM Fluorescence Reader brings a new generation in fluorescence technology to users of the PyroGene® Recombinant Factor C Endotoxin Detection Assay. This fluorescence microplate reader is optimized for Lonza’s PyroGene® Assay, bringing new and improved technology to the laboratory.
You May Also Need...
Product Overview
The PyroWave® XM Fluorescence Reader is a part of the quantitative endotoxin detection system that supports the PyroGene® rFC Endpoint Fluorescent Assay. This reader replaces the Lonza Flx800TM LBS reader, bringing in a new generation in fluorescence technology to users of the PyroGene® Assay. Optimized specifically for Lonza's PyroGene®, this reader brings new and improved technology to the laboratory. The PyroWave® XM reader offers numerous enhancements in incubation, optics, automation capability, and overall reader maintenanceand robustness. Controlled by Lonza's WinKQCL® Endotoxin and Analysis Software, version 5.3 and higher, Lonza delivers a high performance and easy to use system for users interested in an alternative to the horseshoe crab-based endotoxin detection test methods.
On-site service and preventative maintenance contracts are available to help ensure that your instrument is working properly.
Technical Specifications
- Read Capabilities: Fluorescence, Luminescence**, TRF**, FP**
 - Read Position: Top read
 - Light Source: Xenon Flash
 - Detection: High Performance Photo Multiplier Tube
 - Fluorescence Sensitivity: Fluorescein @ 1pM/well in a 96 well plate
 - Wavelength range: 200 – 850nm**
 - Temperature control: ±0.2°C at 37°C
 - Power: 100-240 volts AC 50/60 Hz
 - Dimensions: 39.1 cm W x 47.2 cm D x 32.8 cm H (15.4" W x 18.6' D x 12.9"H)
 - Filters Included: One easy-to-swap filter cube with the following filter configuration:
 
| Assay Type | Excitation Filter (nm) | Emission Filter (nm) | Dichroic Filter (nm) | 
Pyrogene  |              380/20 | 440/30 | 400 | 
| Fluorescein | 485/20 | 528/20 | 510 | 
**Additional Filter cubes and filters must be purchased for additional wavelengths and read capabilities
Request More InfoBenefits
- Improved PyroGene® Assay Performance
 - Reduced Reader maintenance
 - Automation compatible
 - High perfornance optics
 - 4-ZoneTM Incubation at 37°C
 
Applications
- Parenterals
 - Biologics
 - Medical devices
 - Dialysis
 - Compounding
 - Water analysis
 - R&D
 