text.skipToContent text.skipToNavigation
Need help? Please contact us

PyroGene™ Bulk Recombinant Factor C Endpoint Fluorescent Assay

PyroGene™ Bulk Recombinant Factor C Endpoint Fluorescent Assay

Catalog #: 50-658NV

Recombinant Factor C Endpoint Fluorescent Assay for endotoxin testing up to 2,880 tests.

Compare

EA

Product Overview

The PyroGeneTM Recombinant Factor C Assay is the evolution of endotoxin detection testing. Lonza scientists have developed a recombinant form of Factor C, the first component in the horseshoe crab clotting cascade activated by endotoxin. Recombinant Factor C (rFC) is activated by endotoxin binding, and the active enzyme then cleaves a synthetic substrate, resulting in the generation of a fluorogenic compound.PyroGeneTM rFC works through a single enzymatic step compared to the multiple step enzymatic process necessary for LAL assays.

The reaction is run in a 96-well microplate and is measured at time zero and after a one-hour incubation in a fluorescent microplate reader using excitation/emission wavelengths of 380/440 nm.  In the presence of endotoxin, activated rFC will cleave the fluorogenic substrate,causing the solution to fluoresce.The log net fluorescence is proportional to the log endotoxin concentration and is linear in the 0.005 -5.0 EU/ml range.

 

Advantagesof the PyroGeneTM rFC Assay:

  • Endotoxin specific, recombinant technology eliminates false-positive glucan reactions
  • Predictable, reliable lot-to-lot assay performance
  • Sustainable resource –  no animal utilization
  • Endpoint fluorescent assay, comparable to other quantitative LAL methods
  • 510(K) submissions have been approved by the FDA using PyroGeneTM rFC Assay as a final release test
  • Comprehensive FDA Master File

The PyroGeneTM rFcAssay is equivalent to other photometric endotoxin methods that use LAL to detect endotoxins according to the parameters listed in the USP chapter<<1225>> “Validation of Compedial Procedures”. These parameters include linearity, specificity, precision, accuracy, and limit of detection.

Lonza and the PyroGeneTMrFC Assay are leading the way through the evolution of endotoxin detection. 

Request More Info

Benefits

  • Sensitivity range from 0.005 to 5 EU/ml
  • Higher endotoxin specificity through the elimination of false positive glucan reactions
  • Less lot-to-lot variability
  • Security of supply
  • FDA acknowledged alternative to LAL

Applications

  • In-process testing
  • Final product release testing
  • Water testing
  • Testing plant-based material

Storage and Content

  • 30 x 96 tests/vialrFC enzyme solution
  • 30 x 6 mL/vial fluorogenic substrate
  • 30 x 5 mL/vial rFC assay buffer
  • 10 vials endotoxin
Return to Top

SDS, CoA, and Instructions

Safety Data Sheets (SDS)

Choose a language to view the SDS.

Certificate of Analysis (CoA)

Please enter Lot Number, including all zeros, located on the product label and please take into account that it is case sensitive.

  • Instructions - PyroGene® Assay (English)

    Detailed instructions for performing the PyroGene® Recombinant Factor C Endpoint Fluorescent Assay
Return to Top

Educational Material

Brochures, White Papers etc.

  • White Paper - PyroGene® Recombinant Factor C Assay – Endotoxin Testing: It's Time to Embrace the 'Alternative'

    This white paper addresses topics such as: the growing demand of a natural resource, benefits of the synthetic version of Factor C and how to validate the PyroGene® rFC Assay.
  • Troubleshooting Guide - PyroGene® Recombinant Factor C Assay Procedure

    This is a step-by-step guide depicting how to perform the PyroGene® Recombinant Factor C assay.
  • Instructions - PyroGene® Assay (English)

    Detailed instructions for performing the PyroGene® Recombinant Factor C Endpoint Fluorescent Assay
Return to Top